Mitral valve training › Guides › Bioprosthetic mitral valve
Bioprosthetic mitral valve on echo: function and leaks
What to look for: Sewing ring, stent posts, thin cusps; a leak inside or outside the ring.
Watch it in the simulator →Practise random casesKey findings
- A bioprosthesis shows a sewing ring, stent posts and thin, mobile cusps.
- Valvular jets start inside the sewing ring, paravalvular jets outside it. Describe paravalvular leaks on the surgical (atrial) view as a clock face, with the aortic valve at 12 o’clock and the LA appendage at 9 o’clock.
- Structural valve deterioration: thickened or calcified cusps, reduced opening, or a torn, prolapsing cusp.
Grading prosthetic function
- Normal mitral prosthesis: peak E <1.9 m/s, mean gradient ≤5 mmHg, VTI ratio (prosthesis / LVOT) <2.2, effective orifice area ≥2.0 cm², PHT <130 ms. Significant stenosis is suggested by peak E ≥2.5 m/s, mean gradient >10 mmHg, VTI ratio >2.5, orifice area <1.0 cm² and PHT >200 ms; the call is surest when most of them agree.
- Report the heart rate: a fast rate, high flow and patient–prosthesis mismatch also raise the velocities and gradient, and some bioprostheses run slightly higher.
- In a mechanical valve, high velocities with a normal PHT (<130 ms) point to significant MR hidden in the acoustic shadow, not to stenosis: peak E ≥1.9 m/s, VTI ratio ≥2.5 and mean gradient ≥5 mmHg. With both the velocity and the VTI ratio raised, specificity is close to 100%; flow convergence on the LV side is specific but often not seen.
- Grade valvular and paravalvular regurgitation alike: jet size and origin, flow convergence, CW density, pulmonary vein flow and LV size, often best seen with TOE.
Pitfalls
- The sewing ring and stent posts can shadow part of the LA in apical views and hide a jet: use off-axis views, and TOE.
In the simulator every case varies the anatomy, the jets and the measurements: watch the lesion in Learn, then grade new cases in Practice and compare your answer with the exact one.
Related
Edge-to-edge repair (TEER clip) · Surgical repair (annuloplasty ring) · Mechanical mitral valve
Educational simulation to use under the supervision of a clinical tutor — not for clinical use.